Coordinated ventilation has a role

This is in reference to “Controlling the Openings: Is This the Future of Ventilation?” by Sean Gray (Fire Engineering, October 2014) and, in general, to certain fire departments’ application of the National Institute of Standards and Technology (NIST) fire studies. I believe many are applying the science without peer review and without considering the application of appropriate gallons per minute (gpm) coordinated with and just after ventilation and without further study that would address the use of positive-pressure ventilation (PPV)/positive-pressure attack (PPA), including PPV studies by NIST in 2010.

NIST has provided us with critical information that has proven what many have already applied for years: Put water on the fire. What we call “blitz” and others call “hitting hard from the yard,” “resetting the fire,” and so on, has proven to be beneficial time and again and has almost no downside when done correctly. NIST has confirmed that water doesn’t push fire; that the smooth bore nozzle is preferable over the fog nozzle; and that putting water on the fire, and even on explosive gases (smoke and heat), in almost all instances makes the environment safer for firefighters and civilians. This includes water from the exterior prior to entry but also includes water directed above and in front of advancing crews, cooling the gases above as we make entry. I believe numerous firefighter lives will be saved from extreme fire behavior (flashover, for example) when this becomes the norm in our culture.

NIST has also provided us with excellent science on ventilation. And that’s what it is: science, information we can use to better our understanding of fire behavior and growth. An issue, however, is that the current studies are only addressing natural ventilation. What is not being addressed is an appropriate coordinated flow path and adequate gpm at each juncture in the science and in its application.

As Gray attests, “The fire gets bigger if you provide a ventilation opening.” Yes, and we should never ventilate until we are prepared to enter with an appropriately charged handline just after we ventilate. This may be coordinated PPA, or it may be vertical ventilation. We now know that it is nearly impossible to completely ventilate the British thermal units (Btus) of nonlegacy (plastics and so on) fires using natural ventilation.

What is not addressed is NIST’s own science, which demonstrated that PPV “created slightly lower gas temperatures in the fire room and significantly lowers gas temperatures in the adjacent corridor” as well as improves “visibility significantly.” (http://www.nist.gov/fire/ppv.cfm)

Regardless, we are not attempting to fully ventilate the Btus when we perform ventilation. We are attempting to make the atmosphere more tenable for the approaching handline-protected fire crews. To that end, ventilation-PPV and vertical-when performed in a coordinated fashion, has been successful, as any experienced firefighter will attest. Though we are feeding oxygen to the fire, the gases begin to move away from the compartment we are entering, and the fire becomes more visible and is safer to approach with a charged handline.

Some have recently begun attributing close calls and line-of-duty deaths to leaving the entrance door open and are developing guidelines dictating that the door be held closed on the handline. For instance, Gray attributes the extreme fire behavior that injured four firefighters to leaving the front door open when, in fact, he details the larger problem: They entered and then broke windows. The after-action report said four windows and two sliding glass doors were opened while the firefighters were inside on the second floor. That is not coordinated. We don’t set up ventilation while firefighters are inside.

There were also critical communication lapses at that fire. It is easy to attribute sudden extreme fire behavior to simply leaving the door open when, on any close call, the entire picture needs to be brought into focus, and details such as a lack of coordinated ventilation, a lack of appropriate gpm, a communication lapse, and a lack of command are often overriding factors.

When we attempt to keep the fire in a ventilation-controlled state by underventilating and minimizing ventilation openings-for example, leaving the door shut-we may decrease visible burning, but we leave the area full of explosive products of combustion and in a ready state to explode into extreme fire behavior. We cannot guarantee control of the structure; therefore, on approach, anything can happen: A window can fail, someone can inadvertently open a door or a window, or the small opening we left for our hoselines in the supposedly closed door can feed or draw those explosive products, and we’re then left in the sudden extreme fire behavior created by our underventilation.

The NIST science is absolutely critical and needs to be implemented when developing our tactics. We have to be cautious as we move forward and ensure we understand all aspects of the science and include our fireground experience when evolving our strategies and tactics. Coordinated ventilation still has a place in our offensive attacks today.

David Leonard
Captain
Austin (TX) Fire Department

Sean Gray responds: I appreciate David Leonard’s taking the time to read the article and contribute to an educational discussion. One of the misfortunes of written communication is that there are often many variables in interpretation. I completely agree with him concerning coordinated ventilation. All of the Underwriters Laboratories (UL)/NIST studies on ventilation state that coordination is critical. By “controlling the openings,” you are coordinating ventilation by controlling the fire.

I understand the concern about the combustible gases. I had the same thoughts until I witnessed firsthand the tests in Spartanburg, South Carolina, this past May. As I sat and watched this research burn of an acquired structure, I was expecting the gases at the first-floor level to get worse if you closed the front door. It was actually the opposite. What occurs by controlling the openings is that the air is being taken away from the fire, slowing the combustion process. This, in turn, decreases the combustible gases. All of the UL Fire Service Research Institute (FSRI) studies are peer reviewed by firefighters from around the country who serve as technical panel members.

Air flow from a nozzle can change the flow path in a fire and will also disrupt visibility. Additionally, it can move gases to portions of the structure you don’t want them in. There is an UL-FSRI positive-pressure attack (PPA) study underway, and my personal observations are that the fire will create pressure and cause gases to flow in and out of rooms that are not in the flow path. This just naturally happens.

In a ventilation-limited fire, gas temperatures drop below the piloted ignition temperature of the gases; thus, they are no longer “explosive.” This is shown on the growth curves from the horizontal, vertical, and PPA studies.

I would prefer to put water on gases that are 400˚F because we’ve controlled the air rather than on 1,100˚F gases that may be more hazardous to occupants and will require more water.

There is one more factor. Do we know where the fire is located? If not, ventilating will allow the fire to grow until we find it. Sometimes, this may take only one minute, but it could take up to 10 minutes. There is an average of 100 seconds in a single-story residential and 200 seconds in a two-story residential to get water on the fire once a flow path has been created. It comes down to operational efficiency. How good is your crew or your department? How quickly can you get water on the fire? Ideally, water application followed immediately by smoke removal is coordinated ventilation.

Sean Gray
Lieutenant
Cobb County (GA) Fire and
Emergency Services

Dave McGlynn and Brian Zaitz

The Training Officer: The ISFSI and Brian Zaitz

Dave McGlynn talks with Brian Zaitz about the ISFSI and the training officer as a calling.
Conyers Georgia chemical plant fire

Federal Investigators Previously Raised Alarm About BioLab Chemicals

A fire at a BioLabs facility in Conyers, Georgia, has sent a toxic cloud over Rockdale County and disrupted large swaths of metro Atlanta.